Knauf Pipe & Tank Insulation

Description
Knauf Pipe and Tank Insulation is a semi-rigid fiber glass
board in roll form faced with a factory-applied FSK or ASJ vapor
retarder, or a glass mat facing. The glass fibers are adhered
perpendicular to the jacketing for flexibility and easy
installation.
Application
Knauf Pipe and Tank Insulation is typically used on tanks,
vessels and large-diameter pipes. It can be used for any curved or
irregular surfaces that require finished characteristics of rigid
fiber glass insulation.
Features and Benefits
Excellent Thermal Properties
- Low thermal conductivity ratings to 850°F (454°C).
Low-Cost Installation
- Flexible.
- Easy to handle and fabricate.
Inventory Savings
- No need to stock multiple sizes.
- Various thicknesses available to meet all your pipe and tank
insulation needs.
Resists Damage
- Tough and durable.
- Resists damage in shipment and during and after
installation.
Resists Microbial Growth
- Does not promote the growth of fungi or bacteria.
- Will not rot or sustain vermin.
Non-Corrosive
- Will not accelerate corrosion of aluminum, steel or
copper.
Specification Compliance
- ASTM C 795
- NRC 1.36
- MIL-I-24244C
- ASTM C 1136
- Type I, II, III, IV (ASJ)
- Type II, IV (FSK)
- HH-B-100B (jackets)
- Type I and II (ASJ)
- Type II (FSK)
- HH-I-558C; Form A, Class 3
Technical Data
Temperature Range (ASTM C 411)
- Operating Temperature to 850°F (454°C).
Compressive Strength (ASTM C 165)
- Not less than 150 PSF (7.18 kPa) at 10% deformation for 2" (51
mm) thickness.
- Not less than 275 PSF (13.2 kPa) at 10% deformation for 3" (76
mm) thickness.
Water Vapor Transmission (ASTM E 96, Procedure A)
- Both FSK and ASJ vapor retarders have a maximum water vapor
transmission rate of .02 perms.
Puncture Resistance (TAPPI Test T803) (Beach Units)
- FSK facing: 25
- ASJ facing: 50
Surface Burning Characteristics
- Does not exceed 25 Flame Spread, 50 Smoke Developed when tested
in accordance with ASTM E 84, NFPA 255 and UL 723.
Linear Shrinkage (ASTM C 356)
Application & Specification Guidelines
Precautions
- ASJ and FSK jackets should not be used if outer-surface
temperature exceeds 150°F (66°C)
- During initial heat-up to operating temperatures above 350°F
(177°C), a slight odor and some smoke may be given off as a portion
of the bonding material used in the insulation begins to undergo
and controlled decomposition.
- If natural convection is not adequate in confined areas, forced
ventilation should be provided in order to protect against any
harmful fumes and vapors that might be generated.
- Care must also be taken when using sealants, solvents, or
flammable adhesive during installation.
Storage
- Protect stored insulation from water damage and other
abuse.
- Protect from welding sparks and open flame.
- Cartons are not designed for outside storage.
Preparation
- Apply the product on clean, dry surfaces.
Application
For easy installation of Knauf Pipe and Tank Insulation simply
follow these guidelines.
- Refer to the Stretch-out Chart (below) to find the appropriate
length to cut for the specific pipe size. Be sure to add an
additional 2" (51 mm) to 4" (102 mm) for your staple flap.
- Cut your stretch-out length and wrap the material around the
iron pipe to ensure the proper fit.
- Staple the lap on 3" (76 mm) centers with outward clinching
staples.
- Butt edges shall be firmly secured, and butt strips matching
the jacket shall be applied at each joint.
THERMAL EFFICIENCY (ASTM C 177)
| Mean Temperature |
Mean Temperature
(SI) |
k |
k (SI) |
| 100°F |
38°C |
.26 |
.037 |
| 200°F |
93°C |
.35 |
.050 |
| 300°F |
149°C |
.45 |
.065 |
| 400°F |
204°C |
.57 |
.082 |
| 500°F |
260°C |
.75 |
.108 |
FORMS AVAILABLE
|
Thickness |
Width* |
Length |
| 1" (25 mm) |
36" (914 mm) |
48' (14.63 m) |
| ½" (38 mm) |
36" (914 mm) |
32' (9.75 m) |
| 2" (51 mm) |
36" (914 mm) |
24' (7.32 m) |
| 2½" (64 mm) |
36" (914 mm) |
19' (5.79 m) |
| 3" (76 mm) |
36" (914 mm) |
16' (4.88 m) |
| 3½" (89 mm) |
36" (914 mm) |
14' (4.67 m) |
| 4" (102 mm) |
36" (914 mm) |
12' (3.66 m) |
*Cut-to-length sizes also
available
STRETCH-OUTS*
Nominal Iron
Pipe Size |
Iron Pipe
Outside Diameter |
|
Thickness |
|
|
| |
1"
(25 mm) |
1½"
(38 mm) |
2"
(51 mm) |
3"
(76 mm) |
10"
(254 mm) |
10¾"
(273 mm) |
40⅛"
(1019 mm) |
43¼"
(1099 mm) |
46⅜"
(1178 mm) |
52⅝"
(1337 mm) |
12"
(305 mm) |
12¾"
(324 mm) |
46⅜"
(1178 mm) |
49½"
(1257 mm) |
52¾"
(1340 mm) |
59"
(1499 mm) |
14"
(356 mm) |
14"
(356 mm) |
50⅜"
(1280 mm) |
53½"
(1359 mm) |
56⅝"
(1438 mm) |
62⅞"
(1597 mm) |
16"
(406 mm) |
16"
(406 mm) |
56⅝"
(1438 mm) |
59¾"
(1518 mm) |
62⅞"
(1597 mm) |
69⅛"
(1756 mm) |
18"
(457 mm) |
18"
(457 mm) |
62⅞"
(1597 mm) |
66"
(1676 mm) |
69⅛"
(1756 mm) |
75½"
(1918 mm) |
20"
(508 mm) |
20"
(508 mm) |
69⅛"
(1756 mm) |
72⅜"
(1838 mm) |
75½"
(1918 mm) |
81¾"
(2076 mm) |
22"
(559 mm) |
22"
(559 mm) |
75½"
(1918 mm) |
78⅝"
(1997 mm) |
81¾"
(2076 mm) |
88"
(2235 mm) |
24"
(610 mm) |
24"
(610 mm) |
81¾"
(2076 mm) |
84⅞"
(2156 mm) |
88"
(2235 mm) |
94⅜"
(2397 mm) |
26"
(660 mm) |
26"
(660 mm) |
88"
(2235 mm) |
91⅛"
(2315 mm) |
94⅜"
(2397 mm) |
100⅝"
(2556 mm) |
28"
(711 mm) |
28"
(711 mm) |
94⅜"
(2397 mm) |
97½"
(2477 mm) |
100⅝"
(2556 mm) |
106⅞"
(2715 mm) |
30"
(762 mm) |
30"
(762 mm) |
100⅝"
(2556 mm) |
103¾"
(2635 mm) |
106⅞"
(2715 mm) |
113⅛"
(2873 mm) |
32"
(813 mm) |
32"
(813 mm) |
106⅞"
(2715 mm) |
110"
(2794 mm) |
113⅛"
(2873 mm) |
119½"
(3035 mm) |
34"
(864 mm) |
34"
(864 mm) |
113⅛"
(2873 mm) |
116¼"
(2953 mm) |
119½"
(3035 mm) |
125¾"
(3194 mm) |
36"
(914 mm) |
36"
(914 mm) |
119½"
(3035 mm) |
122⅝"
(3115 mm) |
125¾"
(3194 mm) |
132"
(3353 mm) |
38"
(965 mm) |
38"
(965 mm) |
125¾"
(3194 mm) |
128⅞"
(3273 mm) |
132"
(3353 mm) |
138¼"
(3512 mm) |
40"
(1016 mm) |
40"
(1016 mm) |
132"
(3353 mm) |
135⅛"
(3432 mm) |
138¼"
(3512 mm) |
144⅝"
(3673 mm) |
42"
(1067 mm) |
42"
(1067 mm) |
138¼"
(3512 mm) |
141½"
(3594 mm) |
144⅝"
(3673 mm) |
150⅞"
(3832 mm) |
* Additional 2" (51 mm) to 4" (102 mm) shouild be added for lap.