Knauf ET Panel

ET Panel

Description

Knauf Elevated Temperature Panel 1000° is a semi-rigid thermal insulation board (2.4 PCF, 38.4 kg/m3) made from highly resilient, inorganic glass fibers bonded by a high-temperature thermosetting resin.

Application

Knauf Elevated Temperature Panel 1000° is suitable for use in industrial heating applications to 1000°F (538°C), such as high-temperature panel systems for ducts and precipitators, boilers, vessels and industrial ovens. It is ideal for use in metal mesh blankets.

Features and Benefits

Excellent Thermal Properties

  • Reduces operating cost.

Low Installed Cost

  • Lightweight.
  • Easy to fabricate.
  • Sizes up to 4' x 10' available.

Polybag and Sleeve Packaging

  • Damage resistant.
  • Reduces storage space.

Resilient Fiber Glass

  • Maintains integrity at elevated temperatures.

Specification Compliance

In U.S.:

  • ASTM C 612; Type II and III
  • ASTM C 795
  • HH-I-558C; Form A, Class 1, 3
  • MIL-I-24244C
  • NRC Reg. Guide 1.36
  • USCG 164.109/17/0

In Canada:

  • CAN/ULC S102-M88
  • T.C.270.F1.316
  • CGSB 51-GP-10M
  • DND 15280-02 E2

Technical Data

Surface Burning Characteristics

  • Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ASTM E 84, CAN/ULC S102-M88, and UL 723.

Water Vapor Sorption (ASTM C 1104)

  • 0.1% or less by volume.

Corrosiveness (ASTM C 665)

  • Will not accelerate corrosion of steel.

Temperature Limit (ASTM C 411)

  • Up to 1000°F (538°C).

Resistant to Mold Growth (ASTM C 1338)

  • No growth.

Application and Specification Guidelines

Precautions

  • During initial heat-up to operating temperatures above 350°F (177°C), a slight odor and some smoke may be given off as a portion of the bonding material used in the insulation begins to undergo a controlled decomposition.
  • If natural convection is not adequate in confined areas, forced ventilation should be provided in order to protect against any harmful fumes and vapors that might be generated.

Storage

  • Protect material from water damage or other abuse. Cartons are not designed for outside storage. Vacuum packaged material can be stored outside if care is taken not to puncture the polybag.

Preparation

  • Apply the product on clean, dry surfaces.

Application

  • There is no heat-up cycle required for Knauf ET Panel 1000°.
  • The product should be secured with welded pins and washers, or studs and washers, and covered with sheet metal. An alternate method entails covering the insulation with a metal mesh and insulating cement, canvassing, and painting.
  • Pins and washers shall be located a maximum of 4" (102 mm) from each edge and spaced no greater than 16" (406 mm) on center.
  • Care should be taken to avoid over compressing the insulation with the retaining washer.
  • Dual-layer installation with staggered joints is recommended for applications where temperatures meet or exceed 550°F (288°C) and designed thickness is over 3" (76 mm).
  • When using the product at 1000°F (538°C), it is recommended that no more than 6" (152 mm) thickness be used.

Caution

Fiber glass may cause temporary skin irritation. Wear long-sleeved, loose-fitting clothing, head covering, gloves, and eye protection when handling and applying material. Wash with soap and warm water after handling. Wash work clothes separately and rinse washer. A disposable mask designed for nuisance type dusts should be used where sensitivity to dust and airborne particles may cause irritation to the nose and throat.

Notes

The chemical and physical properties of Knauf ET Panel 1000° represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. Check with your Knauf regional office to assure information is current.
 
THERMAL EFFICIENCY (ASTM C 177)

Mean

Temperature

Mean

Temperature (SI)

k k (SI)
100°F 38°C .25 .036
200°F 93°C .32 .046
300°F 149°C .40 .058
400°F 204°C .52 .075
500°F 260°C .68 .098
 
STANDARD SIZES
Thickness Width Length
1" (25 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
11/2" (38 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
2" (51 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
21/2" (64 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
3" (76 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
31/2" (89 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
4" (102 mm) 24" (610 mm) 48" and 96"
(1219 mm and 2438 mm)
 
MADE-TO-ORDER SIZES
Thickness Width Length

1"

(25 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

11/2"

(38 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

2"

(51 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

21/2"

(64 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

3"

(76 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

31/2"

(89 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)

4"

(102 mm)

24" to 48"
(610 mm to 1219 mm)
48" and 96"
(1219 mm and 2438 mm)