Knauf Equipment Liner M is a black flexible fiber glass blanket with a facing adhered to the air stream side. The product provides thermal and acoustical insulation while providing a smooth, tough air stream surface which resists damage during installation and operation.

Application

It is used to provide noise reduction and thermal insulation for equipment (air conditioning, heating)   where air erosion resistance is required. The product is designed for systems operating at temperatures up to 250°F (121°C) and velocities up to 6000 fpm (1829 mpm).

Technical Data

Fire Resistance

  • Meets NFPA 90A and NFPA 90B Standards for fire safety.

Temperature Range (ASTM C 411)

  • Up to 250°F (121°C).

Air Velocity (ASTM C 1071)

  • Maximum 6000 fpm (1829 mpm).

Water Vapor Sorption (ASTM C 1104)

  • Less than 3% by weight

Surface Burning Characteristics (UL/ULC Listed)

  • When tested in accordance with ASTM E 84, UL 723, CAN 4-S102, and NFPA-255, Knauf Equipment Liner M does not exceed 25 Flame Spread, 50 Smoke Developed

Microbial Growth (ASTM C 1338, G 21, G 22)

  • The airstream surface mat facing is treated with an EPA-registered anti-microbial agent to aid in the prevention of fungal and bacterial growth.

Fiber Glass and Mold

Fiber glass insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated with organic materials. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water.

Notes

The chemical and physical properties of Knauf Equipment Liner M represent typical average values determined in accordance with accepted test methods. The data is subject to normal variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these, or any other material under actual fire conditions.
 
Check with your Knauf sales representative to assure information is current.
 
SOUND ABSORPTION COEFFICIENTS (ASTM C 423, Type A Mounting)
1/3 Octave Band Center Frequency (cycles/sec)
Type
125
250
500
1000
2000
4000
NRC
1.5 PCF
(24 kg/m3)
    ½''
 
  (13 mm)
 
.20
 
.45
 
.51
 
  .55
 
  .61
 
  .64
 
.45
 
    1''
 
  (25 mm)
 
.18
 
.36
 
.59
 
  .86
 
  .95
 
  .90
 
.70
 
    1½''
 
  (38 mm)
 
.35
 
.51
 
.83
 
  .93
 
  .97
 
  .96
 
.80
 
    2''
 
  (51 mm)
 
.34
 
.64
 
.96
 
1.03
 
1.00
 
1.03
 
.90
 
2.0 PCF
(32 kg/m3)
    ½''
 
  (13 mm)
 
.09
 
.14
 
.40
 
  .60
 
  .73
 
  .82
 
.45
 
    1''
 
  (25 mm)
 
.25
 
.35
 
.69
 
  .89
 
  .96
 
1.01
 
.70
 
    1½''
 
  (38 mm)
 
.27
 
.55
 
.87
 
  .99
 
1.00
 
  .98
 
.85
 
 
THERMAL CONDUCTIVITY (ASTM C 518) @ 75˚F Mean
Density (PCF)
K Value @ 75°F (24°C)
1.5
.25
2.0
.24
 
FORMS AVAILABLE
Density
 
Thickness
Width
Length
1.5 PCF
(24 kg/m3)
½''
 
(13 mm)
 
24'' (610 mm)
34''-36 '' (864 mm-915 mm)
46''-48'' (1168 mm-1219 mm)
58''-60'' (1473 mm-1524 mm)
70''-72'' (1778 mm-1829 mm)
100'
 
(30.48 m)
 
¾''
 
(19 mm)
 
100'
 
(30.48 m)
 
1''
 
(25 mm)
 
100'
 
(30.48 m)
 
1½''
 
(38 mm)
 
50'
 
(15.24 m)
 
2''
 
(51 mm)
 
50'
 
(15.24 m)
 
2.0 PCF
(32 kg/m3)
½''
 
(13 mm)
 
100'
 
(30.48 m)
 
1''
 
(25 mm)
 
50'
 
(15.24 m)
 
1½''
 
(38 mm)
 
50'
 
(15.24 m)
 
 